Austrian Post 5.99 DPD courier 6.49 GLS courier 4.49

Effect Of Orientation And Insulation On Temperature In Buildings

Language EnglishEnglish
Book Paperback
Book Effect Of Orientation And Insulation On Temperature In Buildings Puneet Jain
Libristo code: 06974944
Publishers LAP Lambert Academic Publishing, November 2011
Reduction of energy consumption in buildings is one of the main concerns worldwide and it is a serio... Full description
? points 117 b
49.44 včetně DPH
In stock at our supplier Shipping in 9-11 days
Austria Delivery to Austria

30-day return policy


You might also be interested in


gestion des competences au maroc Lamya Temnati / Paperback
common.buy 184.42
COMING SOON
Experiments in Plant Tissue Culture John H. Dodds / Paperback
common.buy 21.18
Investor Relations Deutscher Investor Relations Kreis E. V. / Paperback
common.buy 58.86
George Berkeley in America Gaustad / Paperback
common.buy 47.20
Biosensores Amperometricos Mohammed ElKaoutit / Paperback
common.buy 85.20
Lure of Images David Morgan / Hardback
common.buy 222.21
Kostenrechnung F r Rechenzentren Christina Tiedemann / Paperback
common.buy 58.86

Reduction of energy consumption in buildings is one of the main concerns worldwide and it is a serious challenge particularly in desert regions. In India there are many regions where desert conditions prevail. In this study the effect of some of the parameters such as (i) insulating material on the external walls and roof and (ii) the orientation of the building on indoor thermal environment has been simulated using commercial software Design Builder . The insulating material was selected from the Design Builder s material library and four different orientations of the building i.e. 0o, 30o, 60o and 90o were selected. The building adopted for the simulation is cuboid in shape has 12 flats four flats on each floor. The building is located at Jaipur in India. From the simulation study, it was found that maximum temperature of indoor air during summer, averaged over all the flats, drops by 3.82 oC when insulation is used; the existing orientation of the building (0o orientation) gives lowest maximum temperature of indoor air during summer and of the twelve flats, flats on the ground floor are most comfortable during summer.

About the book

Full name Effect Of Orientation And Insulation On Temperature In Buildings
Language English
Binding Book - Paperback
Date of issue 2012
Number of pages 100
EAN 9783659251177
Libristo code 06974944
Weight 167
Dimensions 150 x 220 x 6
Give this book today
It's easy
1 Add to cart and choose Deliver as present at the checkout 2 We'll send you a voucher 3 The book will arrive at the recipient's address

Login

Log in to your account. Don't have a Libristo account? Create one now!

 
mandatory
mandatory

Don’t have an account? Discover the benefits of having a Libristo account!

With a Libristo account, you'll have everything under control.

Create a Libristo account